Typical Composition of all-weld Metal
Mechanical Test of weld Metal
Operating Data
| Re-drying: not allowed |
Welding Positions
- All
Polarity
- AC & DC (+), -ve Polarity for root pass only.
المنطقة الصناعية A1, 10 من رمضان, مصر

99 ش Sebak الشارع
ماريلاند - مصر الجديدة - القاهرة - مصر
+2012 2100 5111
+2010 0885 1811
|
| C | Si | Mn | Ni | P | S | Cr | Mo | V | |
| Wt. % | 0.15 | 0.34 | 1.06 | 0.06 | 0.02 | 0.01 | 0.03 | 0.08 | 0.02 |
| Typical According to ASME II part C/SFA 5.1 | 0.20 max. | 1.00 max. | 1.20 max. | 0.3 max. | N.S | N.S | 0.20 max. | 0.30 max. | 0.08 max. |
| Heat Treatment | Yield Strength | Tensile Strength | Elongation L0=5d0 | Impact values In J CVN |
| MPa | MPa | % | – 30 oC | |
| Untreated | 430 | 525 | 27 | 52 |
| Typical According to ASME II part C/SFA 5.1 | ≥ 330 | ≥ 430 | ≥ 22 | ≥ 27 |
| Re-drying: not allowed |
| mm | 2.5mm | 3.25 mm | 4.0mm | 5.0mm |
| L mm | 350 | 350 | 350 | 350 |
| Amps A | 40-85 | 80-125 | 110-160 | 160-210 |